{"id":11865,"date":"2026-06-30T05:59:36","date_gmt":"2026-06-30T05:59:36","guid":{"rendered":"https:\/\/www.kscranegroup.com\/?post_type=posts&#038;p=11865"},"modified":"2026-06-30T06:08:57","modified_gmt":"2026-06-30T06:08:57","slug":"overhead-crane-wire-rope-sizing-without-tables","status":"publish","type":"posts","link":"https:\/\/www.kscranegroup.com\/fil\/posts\/overhead-crane-wire-rope-sizing-without-tables\/","title":{"rendered":"Pagsusukat ng Overhead Crane Wire Rope Nang Walang Mga Mesa \u2014 Mabilisang Paraan ng Formula ng Isang Field Engineer"},"content":{"rendered":"<div class=\"wp-block-rank-math-toc-block\" id=\"rank-math-toc\"><p>Talaan ng mga Nilalaman<\/p><nav><ul><li><a href=\"#1-determine-the-overhead-crane-wire-rope-safety-factor\">1. Tukuyin ang Safety Factor ng Overhead Crane Wire Rope<\/a><\/li><li><a href=\"#2-identify-the-overhead-crane-wire-rope-class\">2. Tukuyin ang Klase ng Wire Rope ng Overhead Crane<\/a><ul><li><a href=\"#class-a-linear-contact-preferred-for-crane-hoisting\">Klase A \u2014 Linear Contact (Mas mainam para sa Pag-angat ng Crane)<\/a><\/li><li><a href=\"#class-b-point-contact-secondary-applications\">Klase B \u2014 Point Contact (Mga Pangalawang Aplikasyon)<\/a><\/li><\/ul><\/li><li><a href=\"#3-the-quick-diameter-formula-for-overhead-crane-wire-rope-sizing\">3. Ang Mabilis na Pormula ng Diametro para sa Pagsukat ng Lubid na Kable ng Overhead Crane<\/a><ul><li><a href=\"#adjusting-for-different-tensile-grades\">Pagsasaayos para sa Iba&#39;t ibang Grado ng Tensile<\/a><\/li><\/ul><\/li><li><a href=\"#4-rope-weight-estimation\">4. Pagtatantya ng Timbang ng Lubid<\/a><\/li><li><a href=\"#5-back-calculating-capacity-from-an-existing-rope\">5. Pagkalkula ng Kapasidad Mula sa Isang Umiiral Nang Lubid<\/a><\/li><li><a href=\"#6-overhead-crane-wire-rope-end-termination-methods\">6. Mga Paraan ng Pagtatapos ng Dulo ng Wire Rope sa Overhead Crane<\/a><\/li><li><a href=\"#appendix-class-b-coefficients-point-contact-ropes\">Apendiks: Mga Koepisyent ng Klase B (Mga Lubid na Pang-ugnay sa Punto)<\/a><\/li><\/ul><\/nav><\/div>\n\n\n\n<p>Kapag ikaw ay nasa isang lugar ng trabaho o nasa isang pulong ng proyekto at may nagtanong ng &quot;anong diameter ng overhead crane wire rope ang kailangan ko para sa X tonelada?&quot;, maaaring wala kang GB\/T 20118 o ISO 2408. Ang artikulong ito ay nagpapakita ng isang mabilisang pormula batay sa coefficient para sa 6\u00d719 at 6\u00d736 na klase ng overhead crane wire rope \u2014 ang dalawang pamilya na sumasaklaw sa mahigit 90% ng mga aplikasyon sa pag-aangat ng crane. Ang pamamaraan ay na-verify laban sa mga karaniwang talahanayan ng GB\/T 20118-2017 na may error margin sa loob ng 2%.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"1-determine-the-overhead-crane-wire-rope-safety-factor\">1. Tukuyin ang Safety Factor ng Overhead Crane Wire Rope<\/h2>\n\n\n\n<p>Ang safety factor ay ang ratio ng minimum na puwersa sa pagsira ng lubid sa kabuuang working load.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Paglalapat<\/th><th>Minimum na Salik sa Kaligtasan<\/th><\/tr><\/thead><tbody><tr><td>Static bracing \/ guy rope (permanenteng tensyon)<\/td><td>3<\/td><\/tr><tr><td>Kagamitan sa pag-angat gamit ang manu-manong kamay<\/td><td>4<\/td><\/tr><tr><td>Kagamitan sa pag-angat na pinapagana<\/td><td>5\u20136<\/td><\/tr><tr><td>Disenyo ng kreyn<\/td><td>Alinsunod sa GB\/T 3811 na kodigo ng disenyo ng kreyn<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Salik sa Kaligtasan ng Overhead Crane Wire Rope<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1217\" height=\"1293\" src=\"https:\/\/www.kscranegroup.com\/wp-content\/uploads\/2026\/06\/1Determine-the-Safety-Factor-of-overhead-crane-wire-rope.png\" alt=\"\" class=\"wp-image-11861\"\/><\/figure>\n\n\n\n<p>Para sa pangkalahatang pagbubuhat gamit ang mga de-kuryenteng kagamitan, gamitin ang default na 5 o 6. Kapag ang karga ay nangangailangan ng pag-access ng mga tauhan o nakasabit sa ibabaw ng kritikal na imprastraktura, pataasin pa.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"2-identify-the-overhead-crane-wire-rope-class\">2. Tukuyin ang Klase ng Wire Rope ng Overhead Crane<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"class-a-linear-contact-preferred-for-crane-hoisting\">Klase A \u2014 Linear Contact (Mas mainam para sa Pag-angat ng Crane)<\/h3>\n\n\n\n<p>6\u00d719 na klase at 6\u00d736 na klase ng mga hibla. Ang mga alambre sa loob ng bawat hibla ay nakaayos upang ang pagdikit ay nangyayari sa mga linya sa halip na sa mga punto, na mas pantay na ipinamamahagi ang stress at naghahatid ng mas mahusay na buhay ng pagkapagod. Ito ang mga karaniwang pagpipilian para sa mga mekanismo ng pag-angat ng crane.<\/p>\n\n\n\n<p>Mga karaniwang konstruksyon: 6\u00d719S-FC, 6\u00d719S-IWRC, 6\u00d736WS-FC, 6\u00d736WS-IWRC, 6\u00d717S, 6\u00d721S, 6\u00d721F, 6\u00d726WS, 6\u00d719W, 6\u00d725F, 6\u00d731WS, 6\u00d729F, 6\u00d737FS, 6\u00d741WS, 6\u00d746WS, 6\u00d749SWS, 6\u00d755SWS.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Code<\/th><th>Ibig sabihin<\/th><th>Katangian<\/th><\/tr><\/thead><tbody><tr><td>W<\/td><td>Warrington (mga salit-salit na laki ng alambre sa panlabas na patong)<\/td><td>Magandang kakayahang umangkop<\/td><\/tr><tr><td>S<\/td><td>Seale (magaspang na panlabas na mga alambre)<\/td><td>Magandang resistensya sa abrasion<\/td><\/tr><tr><td>F<\/td><td>Tagapuno (maliliit na mga alambre ng tagapuno sa pagitan ng mga patong)<\/td><td>Komplikadong istruktura<\/td><\/tr><tr><td>WS<\/td><td>Kompositor ng Warrington-Seale<\/td><td>Pinakamahusay na balanse ng kakayahang umangkop at resistensya sa pagkapagod \u2014 pinakakaraniwan sa mga crane<\/td><\/tr><tr><td>FC<\/td><td>Hibla na Ubod<\/td><td>Nag-iimbak ng pampadulas, mas nababaluktot<\/td><\/tr><tr><td>IWRC<\/td><td>Malayang Wire Rope Core (bakal)<\/td><td>Mas mataas na lakas ng pagsira \u2014 humigit-kumulang 1.08\u00d7 ang katumbas ng FC<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Mga Katangian ng Crane Wire Rope<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"class-b-point-contact-secondary-applications\">Klase B \u2014 Point Contact (Mga Pangalawang Aplikasyon)<\/h3>\n\n\n\n<p>Klase 6\u00d719M at klase 6\u00d737M. Ang mga alambre ay tumatawid sa magkakahiwalay na mga punto, na lumilikha ng mga konsentrasyon ng stress at mas mababang resistensya sa pagkapagod. Pangunahing ginagamit para sa mga static guy rope at mga pangalawang aplikasyon.<\/p>\n\n\n\n<p>Mga karaniwang konstruksyon: 6\u00d719M-FC, 6\u00d719M-IWRC, 6\u00d737M-FC, 6\u00d737M-IWRC.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"3-the-quick-diameter-formula-for-overhead-crane-wire-rope-sizing\">3. Ang Mabilis na Pormula ng Diametro para sa Pagsukat ng Lubid na Kable ng Overhead Crane<\/h2>\n\n\n\n<p>Para sa Class A, 1770 MPa tensile grade, Fiber Core \u2014 ang pinakakaraniwang konpigurasyon ng overhead crane wire rope:<\/p>\n\n\n\n<p>d \u2265 \u221a(T \u00f7 k)<\/p>\n\n\n\n<ul>\n<li>kung saan: k = 0.06<\/li>\n\n\n\n<li>T = ligtas na karga sa pagtatrabaho bawat lubid (tonelada)<\/li>\n\n\n\n<li>d = nominal na diyametro ng lubid (mm)<\/li>\n<\/ul>\n\n\n\n<p>Sa madaling salita: d\u00b2 \u00d7 0.06 = T. Ang parisukat ng diyametro ng lubid sa milimetro na pinarami ng 0.06 ay katumbas ng ligtas na kapasidad sa pagtatrabaho sa tonelada.<\/p>\n\n\n\n<p><strong>Halimbawa:<\/strong> Ang isang 10-toneladang single-part lift ay nangangailangan ng d = \u221a(10 \u00f7 0.06) = \u221a166.7 \u2248 12.9 mm \u2192 i-round up sa <strong>13 milimetro<\/strong> mula sa serye ng karaniwang diyametro.<\/p>\n\n\n\n<p>Ang karaniwang serye ng diyametro (mm) para sa Klase A: 8, 9, 10, 11, 12, 13, 14, 15, 16, 18, 20, 22, 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44, 46, 48, 50, 52, 54, 56. (Mayroong 6 at 7 mm ngunit bihira sa pagbubuhat ng crane; ang 58 at 60 mm ay depende sa partikular na konstruksyon.)<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"adjusting-for-different-tensile-grades\">Pagsasaayos para sa Iba&#39;t ibang Grado ng Tensile<\/h3>\n\n\n\n<p>Ang base coefficient na k = 0.06 ay naaangkop sa 1770 MPa. Para sa bawat grade step na humigit-kumulang 90\u2013100 MPa, isaayos ng \u00b10.003:<\/p>\n\n\n\n<p>Pagtaas sa baitang: k_i = 0.06 + 0.003 \u00d7 i<\/p>\n\n\n\n<p>Pagbaba sa baitang: k_i = 0.06 \u2013 (0.003 \u00d7 i + 0.001)<\/p>\n\n\n\n<p>Kung saan ang i = 0 sa 1770 MPa. Ang serye ng tensile grade: 1570 \u2192 1670 \u2192 1770 \u2192 1870 \u2192 1960 \u2192 2160 MPa.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Grado ng Tensile (MPa)<\/th><th>Fiber Core k<\/th><th>Bakal na Core k (= FC \u00d7 1.08)<\/th><\/tr><\/thead><tbody><tr><td>1570<\/td><td>0.053<\/td><td>0.057<\/td><\/tr><tr><td>1670<\/td><td>0.056<\/td><td>0.061<\/td><\/tr><tr><td>1770<\/td><td>0.060<\/td><td>0.064<\/td><\/tr><tr><td>1870<\/td><td>0.063<\/td><td>0.068<\/td><\/tr><tr><td>1960<\/td><td>0.066<\/td><td>0.071<\/td><\/tr><tr><td>2160<\/td><td>0.073 <\/td><td>0.079<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Talahanayan ng Paghahambing ng Lalim ng Tensile Strength ng Crane Wire Rope<\/figcaption><\/figure>\n\n\n\n<p><strong>Espesyal na kaso para sa 2160 MPa fiber core:<\/strong> Ang kinakalkulang halaga ay 0.072, ngunit ang napatunayang koepisyent ay 0.073 \u2014 dagdagan ng 0.001. Ang eksepsiyon na ito ay nalalapat lamang sa gradong 2160.<\/p>\n\n\n\n<p><strong>Halimbawa:<\/strong> Para sa 1870 MPa fiber core (i = 1), k = 0.06 + 0.003 = 0.063. Ang parehong 10-toneladang karga: d = \u221a(10 \u00f7 0.063) = \u221a158.7 \u2248 12.6 mm \u2192 bilugan hanggang 13 mm.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"4-rope-weight-estimation\">4. Pagtatantya ng Timbang ng Lubid<\/h2>\n\n\n\n<p>Kapag napili na ang diyametro, tinatayang timbang bawat 100 metro:<\/p>\n\n\n\n<p>m_FC = 0.38 \u00d7 d\u00b2 (hibla, Klase A)<\/p>\n\n\n\n<p>m_IWRC = 0.418 \u00d7 d\u00b2 (bakal na core, Klase A)<\/p>\n\n\n\n<p>Kung saan ang m ay ang timbang (kg bawat 100 m) at ang d ay ang diyametro (mm). Ang mga koepisyent ng timbang ay hindi nakadepende sa tensile grade.<\/p>\n\n\n\n<p><strong>Halimbawa:<\/strong> 13 mm na lubid na may hibla \u2192 m = 0.38 \u00d7 169 = 64 kg bawat 100 m. Ang isang 30-metrong bagsakan ay may bigat na humigit-kumulang 19 kg.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5-back-calculating-capacity-from-an-existing-rope\">5. Pagkalkula ng Kapasidad Mula sa Isang Umiiral Nang Lubid<\/h2>\n\n\n\n<p>Kapag nakakita ka ng lubid sa lugar na walang pagkakakilanlan \u2014 walang sertipiko, walang tag, walang marka \u2014 sukatin ang aktwal na diyametro nito at tantyahin ang ligtas na karga nito:<\/p>\n\n\n\n<p>F = 0.06 \u00d7 d\u00b2 (tonelada, Klase A, 1770 MPa, hibla ng hibla)<\/p>\n\n\n\n<p><strong>Halimbawa:<\/strong> Ang isang natagpuang lubid ay may sukat na 16 mm. F = 0.06 \u00d7 256 = 15.4 toneladang ligtas na karga sa pagtatrabaho (sa pag-aakalang 1770 MPa, Class A, FC). Para sa bakal na core: paramihin ng 1.08 \u2192 16.6 tonelada.<\/p>\n\n\n\n<p><strong>Mahalaga:<\/strong> Ipinapalagay ng back-calculation na ito na ang isang bagong lubid ay nasa kondisyong gawa pa lamang. Hindi nito isinasaalang-alang ang pagkasira, kalawang, sirang mga alambre, o pinsala mula sa pagkapagod. Palaging magsagawa ng masusing visual na inspeksyon at suriin ang mga pamantayan sa pagtatapon bago umasa sa isang natagpuang lubid para sa pagbubuhat.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"6-overhead-crane-wire-rope-end-termination-methods\">6. Mga Paraan ng Pagtatapos ng Dulo ng Wire Rope sa Overhead Crane<\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1463\" height=\"1075\" src=\"https:\/\/www.kscranegroup.com\/wp-content\/uploads\/2026\/06\/2Overhead-Crane-Wire-Rope-End-Termination-Methods.png\" alt=\"\" class=\"wp-image-11862\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Paraan<\/th><th>Pamantayan<\/th><th>Pangunahing Panuntunan<\/th><\/tr><\/thead><tbody><tr><td><strong>Mga pang-ipit ng lubid na alambre<\/strong><\/td><td>GB\/T 5976<\/td><td>d \u2264 16 \u2192 3 clip; 16 &lt; d \u2264 20 \u2192 4 na clip; 20 &lt; d \u2264 26 \u2192 5 clip; d &gt; 26 \u2192 6 na clip. Pagitan ng clip = (5\u20136) \u00d7 d<\/td><\/tr><tr><td><strong>Socket ng wedge<\/strong><\/td><td>GB\/T 5793<\/td><td>Balutin nang mahigpit ang buntot sa likod ng wedge; hindi ipinag-uutos ng pamantayang Tsino ang isang backup clip, ngunit ang kasanayan sa US (ASME B30.5) ay nagdaragdag ng isa sa likod ng wedge para sa karagdagang seguridad<\/td><\/tr><tr><td><strong>Ferrule na aluminyo (swaging)<\/strong><\/td><td>\u2014<\/td><td>Nangangailangan ng hydraulic press; mapapatunayan sa pamamagitan ng pagsukat ng deformation<\/td><\/tr><tr><td><strong>Paghihiwalay<\/strong><\/td><td>\u2014<\/td><td>Matang pinagdugtong ng kamay; tradisyonal, bumababa na sa paggamit sa industriya<\/td><\/tr><tr><td><strong>Konikal na socket (ibinuhos na zinc\/resin)<\/strong><\/td><td>\u2014<\/td><td>Mataas na lakas na pagtatapos para sa mga lubid na may malalaking diyametro<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Talahanayan ng Paghahambing ng Pamantayang Pag-aayos ng Lubid na Wire ng Overhead Crane<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1319\" height=\"1193\" src=\"https:\/\/www.kscranegroup.com\/wp-content\/uploads\/2026\/06\/3Overhead-Crane-Wire-Rope-End-Termination-Methods1.png\" alt=\"\" class=\"wp-image-11863\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1011\" height=\"706\" src=\"https:\/\/www.kscranegroup.com\/wp-content\/uploads\/2026\/06\/4Overhead-Crane-Wire-Rope-End-Termination-Methods2.jpg\" alt=\"\" class=\"wp-image-11864\"\/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"appendix-class-b-coefficients-point-contact-ropes\">Apendiks: Mga Koepisyent ng Klase B (Mga Lubid na Pang-ugnay sa Punto)<\/h2>\n\n\n\n<p>Para sa mga lubid na point-contact na klase 6\u00d719M at 6\u00d737M, na hindi gaanong ginagamit sa pag-angat ng crane:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Parameter<\/th><th>Simbolo<\/th><th>Halaga (FC, 1770 MPa)<\/th><\/tr><\/thead><tbody><tr><td>Koepisyent ng base<\/td><td>k<\/td><td>0.053<\/td><\/tr><tr><td>Pagsasaayos ng grado<\/td><td>k_i<\/td><td>0.053 \u00b1 0.003 \u00d7 i (simetriko, walang dagdag na -0.001)<\/td><\/tr><tr><td>Koepisyent ng timbang (FC)<\/td><td>w1<\/td><td>0.35<\/td><\/tr><tr><td>Koepisyent ng timbang (IWRC)<\/td><td>w2<\/td><td>0.40<\/td><\/tr><tr><td>Ligtas na kapasidad (FC)<\/td><td>F<\/td><td>0.053 \u00d7 d\u00b2 (tonelada)<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Lakas ng Class B Crane Wire Rope<\/figcaption><\/figure>\n\n\n\n<p><strong>Halimbawa para sa Klase B, 1570 MPa:<\/strong> k = 0.053 \u2013 (0.003 \u00d7 2) = 0.047.<\/p>\n\n\n\n<p><strong>Mga Pamantayan na Isinangguni<a href=\"https:\/\/openstd.samr.gov.cn\/bzgk\/std\/std_list?p.p1=0&amp;p.p90=circulation_date&amp;p.p91=desc&amp;p.p2=%E8%B5%B7%E9%87%8D%E6%9C%BA\" target=\"_blank\" rel=\"noopener\">Pagtatanong sa mga Pamantayan ng Chinese Crane<\/a>):<\/strong><\/p>\n\n\n\n<ul>\n<li>GB\/T 20118-2017 \u2014 Mga lubid na bakal para sa pangkalahatang layunin (maaaring mapagkunan ng eksaktong minimum na halaga ng puwersa sa pagsira)<\/li>\n\n\n\n<li>GB\/T 5793-2006 \u2014 Mga socket na wedge para sa wire rope<\/li>\n\n\n\n<li>GB\/T 5976-2006 \u2014 Mga pang-ipit ng lubid na alambre<\/li>\n<\/ul>\n\n\n\n<p><strong>Katumpakan ng pamamaraan:<\/strong> Na-verify laban sa mga pamantayang talahanayan ng GB\/T 20118-2017. Ang error ay karaniwang nasa loob ng 2% para sa mga konstruksyon ng lubid na sakop. Ito ay isang praktikal na pamamaraan sa larangan \u2014 para sa mga pangwakas na detalye sa inhinyeriya, palaging i-verify laban sa buong pamantayan.<\/p>\n\n\n\n<p>Kung gusto mong matuto nang higit pa tungkol sa kaligtasan ng mga wire rope ng crane, maaari mong basahin ang artikulong ito: <a href=\"https:\/\/www.kscranegroup.com\/fil\/posts\/replacement-and-installing-wire-rope-on-crane\/\">Pagpapalit at Pag-install ng Wire Rope sa Crane: Mga Pangunahing Pagsasaalang-alang at Tip para sa Pangmatagalang Katatagan<\/a><\/p>","protected":false},"excerpt":{"rendered":"When you are on a job site or in a project meeting and someone asks &#8220;what diameter overhead crane wire rope do I need for X tonnes?&#8221;, you may not have GB\/T 20118 or ISO 2408 at hand. This article pres","protected":false},"featured_media":11873,"parent":0,"menu_order":0,"template":"single-SEO-Table.php","posts_category":[189],"posts_tag":[816,801,817,815,121,820,818,814,813,819],"acf":[],"_links":{"self":[{"href":"https:\/\/www.kscranegroup.com\/fil\/wp-json\/wp\/v2\/xmxposts\/11865"}],"collection":[{"href":"https:\/\/www.kscranegroup.com\/fil\/wp-json\/wp\/v2\/xmxposts"}],"about":[{"href":"https:\/\/www.kscranegroup.com\/fil\/wp-json\/wp\/v2\/types\/posts"}],"version-history":[{"count":5,"href":"https:\/\/www.kscranegroup.com\/fil\/wp-json\/wp\/v2\/xmxposts\/11865\/revisions"}],"predecessor-version":[{"id":11876,"href":"https:\/\/www.kscranegroup.com\/fil\/wp-json\/wp\/v2\/xmxposts\/11865\/revisions\/11876"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kscranegroup.com\/fil\/wp-json\/wp\/v2\/media\/11873"}],"wp:attachment":[{"href":"https:\/\/www.kscranegroup.com\/fil\/wp-json\/wp\/v2\/media?parent=11865"}],"wp:term":[{"taxonomy":"posts_category","embeddable":true,"href":"https:\/\/www.kscranegroup.com\/fil\/wp-json\/wp\/v2\/posts_category?post=11865"},{"taxonomy":"posts_tag","embeddable":true,"href":"https:\/\/www.kscranegroup.com\/fil\/wp-json\/wp\/v2\/posts_tag?post=11865"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}